404 Buenaventura Blvd Inspection Report

General Info

Property Address
404 Buenaventura Blvd
Kissimmee FL 34743
Date of Inspection
4/22/2021
Report ID
20210422-404-Buenaventura-Blvd
Customer(s)
Sandra Madrigal
Time of Inspection
04:30 PM
Real Estate Agent
Inspection Details
In Attendance:
Seller and listing agent
Type of building:
Single Family (2 story)
Approximate age of building:
Over 25 Years
Home Faces:
NE
Temperature:
Over 65 (F) = 18 (C)
Weather:
Clear
Ground/Soil surface condition:
Dry
Rain in last 3 days:
No
Radon Test:
No
Water Test:
No
Comment Key & Definitions

Comment Key or Definitions

The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home.
Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further
inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.

Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for
normal wear and tear.

Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason
for not inspecting.

Not Present (NP) = This item, component or unit is not in this home or building.

Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or
units that can be repaired to satisfactory condition may not need replacement.

 

1. Roofing

The inspector shall inspect from ground level or eaves: The roof covering. The gutters. The downspouts. The vents, flashings, skylights, chimney and other roof penetrations. The general structure
of the roof from the readily accessible panels, doors or stairs.The inspector is not required to: Walk on any roof surface, predict the service life expectancy, inspect underground downspout diverter drainage pipes, remove snow, ice, debris or other conditions
that prohibit the observation of the roof surfaces, move insulation, inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. Walk on any roof areas that appear,
in the opinion of the inspector to be unsafe, and or cause damage. Perform a water test, warrant or certify the roof. Confirm proper fastening or installation of any roof material.
Styles & Materials
Roof Covering:
Architectural
Viewed roof covering from:
Camera Pole
Chimney (exterior):
N/A

 

IN

NI

NP

RR

1.0

Roof Coverings

1.1

Flashings

1.2

Skylights, Chimneys and Roof Penetrations

1.3

Roof Drainage Systems

IN

NI

NP

RR

IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

The roof of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Roof coverings and
skylights can appear to be leak proof during inspection and weather conditions. Our inspection makes an attempt to find a leak but sometimes cannot. Please be aware that the inspector has your best
interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it
relates to the comments in this inspection report.

 

2. Exterior

The inspector shall inspect: The siding, flashing and trim. All exterior doors, decks, stoops, steps, stairs, porches, railings, eaves, soffits and fascias. And report as in need of repair any spacing between intermediate balusters, spindles, or rails for steps, stairways, balconies, and railings that permit the passage of an object greater than four inches in diameter. A representative number of windows. The vegetation, surface drainage and retaining walls when these are likely to adversely affect the structure. And describe the exterior wall covering.

The inspector is not required to: Inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting, Inspect items, including window and door flashings, which are not visible or readily accessible from the ground, Inspect geological, geotechnical, hydrological and/or soil conditions, Inspect recreational facilities, playground equipment. Inspect seawalls, break-walls and docks, Inspect erosion control and earth stabilization measures, Inspect for safety type glass, Inspect underground utilities, Inspect underground items, Inspect wells or springs, Inspect solar, wind or geothermal systems, Inspect swimming pools or spas, Inspect wastewater treatment systems septic systems or cesspools, Inspect irrigation or sprinkler systems, Inspect drain fields or drywells, Determine the integrity of multi-pane window glazing or the thermal window seals.

Styles & Materials
Siding Style:
Lap
Aluminum
Siding Material:
Metal
Exterior Entry Doors:
Wood
Appurtenance:
Porch
Driveway:
Stone

 

IN

NI

NP

RR

2.0

Wall Cladding Flashing and Trim

2.1

Doors (Exterior)

2.2

Windows

2.3

Decks, Balconies, Stoops, Steps, Areaways, Porches, Patio/Cover and Applicable Railings

2.4

Vegetation, Grading, Drainage, Driveways, Patio Floor, Walkways and Retaining Walls (With respect to their effect on the condition of the building)

2.5

Eaves, Soffits and Fascias

IN

NI

NP

RR

IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

The exterior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

 

3. Structural Components

The inspector shall inspect: The basement. The foundation. The crawlspace. The visible structural components. Any present conditions or clear indications of active water penetration observed by the inspector. And report any general indications of foundation movement that are observed by the inspector, such as but not limited to sheetrock cracks, brick cracks, out-of-square door frames or floor slopes.

The inspector is not required to: Enter any crawlspaces that are not readily accessible or where entry could cause damage or pose a hazard to the inspector, Move stored items or debris, Operate sump pumps with inaccessible floats, Identify size, spacing, span, location or determine adequacy of foundation bolting, bracing, joists, joist spans or support systems, Provide any engineering or architectural service, Report on the adequacy of any structural system or component.

Styles & Materials
Foundation:
Poured concrete
Floor Structure:
Slab
Wall Structure:
2 X 4 Wood
Ceiling Structure:
2X4
Roof Structure:
2 X 4 Rafters
Roof-Type:
Gable
Roof-Type:
Gable
Method used to observe attic:
Walked
Attic info:
Attic access

 

IN

NI

NP

RR

3.0

Foundations, Basement and Crawlspace (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.)

3.1

Walls (Structural)

3.2

Columns or Piers

3.3

Floors (Structural)

3.4

Ceilings (Structural)

3.5

Roof Structure and Attic

IN

NI

NP

RR

IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

 

The structure of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

4. Heating / Central Air Conditioning

The inspector shall inspect: The heating system and describe the energy source and heating method using normal operating controls. And report as in need of repair electric furnaces which do not operate. And report if inspector deemed the furnace inaccessible. The central cooling equipment using normal operating controls. The fireplace, and open and close the damper door if readily accessible and operable. Hearth extensions and other permanently installed components. And report as in need of repair deficiencies in the lintel, hearth and material surrounding the fireplace, including clearance from combustible materials.

The inspector is not required to: Inspect or evaluate interiors of flues or chimneys, fire chambers, heat exchangers, humidifiers, dehumidifiers, electronic air filters, solar heating systems, solar heating systems or fuel tanks. Inspect underground fuel tanks. Determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. Light or ignite pilot flames. Activate heating, heat pump systems, or other heating systems when ambient temperatures or when other circumstances are not conducive to safe operation or may damage the equipment. Override electronic thermostats. Evaluate fuel quality. Verify thermostat calibration, heat anticipation or automatic setbacks, timers, programs or clocks. Determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. Inspect window units, through-wall units, or electronic air filters. Operate equipment or systems if exterior temperature is below 60 degrees Fahrenheit or when other circumstances are not conducive to safe operation or may damage the equipment. Inspect or determine thermostat calibration, heat anticipation or automatic setbacks or clocks. Examine electrical current, coolant fluids or gasses, or coolant leakage. Inspect the flue or vent system. Inspect the interior of chimneys or flues, fire doors or screens, seals or gaskets, or mantels. Determine the need for a chimney sweep. Operate gas fireplace inserts. Light pilot flames. Determine the appropriateness of such installation. Inspect automatic fuel feed devices. Inspect combustion and/or make-up air devices. Inspect heat distribution assists whether gravity controlled or fan assisted. Ignite or extinguish fires. Determine draft characteristics. Move fireplace inserts, stoves, or firebox contents. Determine adequacy of draft, perform a smoke test or dismantle or remove any component. Perform an NFPA inspection. Perform a Phase 1 fireplace and chimney inspection.

Styles & Materials
Heat Type:
Electric heat
Energy Source:
Electric
Number of Heat Systems (excluding wood):
Two
Heat System Brand:
CARRIER
Ductwork:
Insulated
Filter Type:
Disposable
Filter Size:
14×20
Cooling Equipment Type:
Air conditioner unit
Cooling Equipment Energy Source:
Electricity
Number of AC Only Units:
Two
Central Air Brand:
CARRIER
Condenser Unit Model Number:
Model number
Extra Info : UNIT 1 MOD# PA14NC042000AAAA UNIT 2 MOD# PA113NA024
Condenser Unit Serial Number:
Serial Number
Extra Info : UNIT 1 SER # 1615X75145 UNIT 2 SER # 0414X60044
Air Handler Model Number:
Model Number
Extra Info : UNIT 1 MOD# FB4CNF042 UNIT 2 MOD# FB4CNF024
Air Handler Serial Number:
Serial Number
Extra Info : UNIT 1 SER# 4915A85118 UNIT 2 SER# 1914A72452
Air Handler Serial Number:
Serial Number
Extra Info : 3920F18491

 

IN

NI

NP

RR

4.0

Heating Equipment

4.1

Normal Operating Controls

4.2

Automatic Safety Controls

4.3

Distribution Systems (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)

4.4

Presence of Installed Heat Source in Each Room

4.5

Chimneys, Flues and Vents (for fireplaces, gas water heaters or heat systems)

4.6

Cooling and Air Handler Equipment

4.7

Normal Operating Controls

4.8

Presence of Installed Cooling Source in Each Room

IN

NI

NP

RR

IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

Comments:

4.8  The air temp test was performed by using thermometers on the air handler of both Air conditioners to determine if the difference in temperatures of the supply and return air are between 14 degrees and 22 degrees which indicates that the unit is cooling as intended. The supply air temperature on your system read 49 degrees, and the return air temperature was 72 degrees. This indicates the range in temperature drop is normal.

4.8 Item 1 (Picture)                                                  4.8 Item 2 (Picture)                                                  4.8 Item 3 (Picture)
The heating and cooling system of this home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection is not meant to be technically exhaustive. The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensed heat contractor would discover. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

 

5. Plumbing System

The inspector shall: Verify the presence of and identify the location of the main water shutoff valve. Inspect the water heating equipment, including combustion air, venting, connections, energy sources, seismic bracing, and verify the presence or absence of temperature-pressure relief valves and/or Watts 210 valves. Flush toilets. Run water in sinks, tubs, and showers. Inspect the interior water supply including all fixtures and faucets. Inspect the drain, waste and vent systems, including all fixtures. Describe any visible fuel storage systems. Inspect the drainage sump pumps testing sumps with accessible floats. Inspect and describe the water supply, drain, waste and main fuel shut-off valves, as well as the location of the water main and main fuel shut-off valves. Inspect and determine if the water supply is public or private. Inspect and report as in need of repair deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously. Inspect and report as in need of repair deficiencies in installation and identification of hot and cold faucets. Inspect and report as in need of repair mechanical drain-stops that are missing or do not operate if installed in sinks, lavatories and tubs. Inspect and report as in need of repair commodes that have cracks in the ceramic material, are improperly mounted on the floor, leak, or have tank components which do not operate.

The inspector is not required to: Light or ignite pilot flames. Determine the size, temperature, age, life expectancy or adequacy of the water heater. Inspect interiors of flues or chimneys, water softening or filtering systems, well pumps or tanks, safety or shut-of valves, floor drains, lawn sprinkler systems or fire sprinkler systems. Determine the exact flow rate, volume, pressure, temperature, or adequacy of the water supply. Determine the water quality or potability or the reliability of the water supply or source. Open sealed plumbing access panels. Inspect clothes washing machines or their connections. Operate any main, branch or fixture valve. Test shower pans, tub and shower surrounds or enclosures for leakage. Evaluate the compliance with local or state conservation or energy standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. Determine the effectiveness of anti-siphon, back-flow prevention or drain-stop devices. Determine whether there are sufficient clean-outs for effective cleaning of drains. Evaluate gas, liquid propane or oil storage tanks. Inspect any private sewage waste disposal system or component of. Inspect water treatment systems or water filters. Inspect water storage tanks, pressure pumps or bladder tanks. Evaluate time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. Evaluate or determine the adequacy of combustion air. Test, operate, open or close safety controls, manual stop valves and/or temperature or pressure relief valves. Examine ancillary systems or components, such as, but not limited to, those relating to solar water heating, hot water circulation.

Styles & Materials
Water Source:
Public
Plumbing Water Supply (into home):
Copper
PVC
Plumbing Water Distribution (inside home):
PVC
Washer Drain Size:
2″ Diameter
Plumbing Waste:
PVC
Water Heater Power Source:
Electric
Water Heater Capacity:
80 Gallon (plenty)
Water Heater Location:
Upper level
WH Manufacturer:
AMERICAN
Water Heater Model Number:
Model Number
Extra Info : SE62-80H-035S
Water Heater Serial Number:
Serial Number
Extra Info : 0043105983

IN

NI

NP

RR

5.0

Plumbing Drain, Waste and Vent Systems

5.1

Plumbing Water Supply, Distribution System and Fixtures

5.2

Hot Water Systems, Controls, Chimneys, Flues and Vents

5.3

Main Water Shut-off Device (Describe location)

IN

NI

NP

RR

IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

Comments:

5.1  The water pressure was recorded at 55 PSI at the time of inspection.
                                 5.1 Item 1 (Picture)
5.2  The water heater was recorded at 132 degrees. 120 degrees and above is considered hazardous. Recommend adjusting the water heater thermostat to a safe temperature. Adjustment should be done by a qualified person or licensed plumber.

5.2 Item 1 (Picture)                                                 5.2 Item 2 (Picture)                                                  5.2 Item 3 (Picture)
5.3  The main water shut off is located outside in the ground.

5.3 Item 1 (Picture)                                                   5.3 Item 2 (Picture)
The plumbing in the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Washing machine drain line for example cannot be checked for leaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed and barely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waiting for closing) rust or deposits within the pipes can further clog the piping system. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

 

6. Electrical System

The inspector shall inspect: The service line. The meter box. The main disconnect. And determine the rating of the service amperage. Panels, breakers and fuses. The service grounding and bonding. A representative sampling of switches, receptacles, light fixtures, AFCI receptacles and test all GFCI receptacles and GFCI circuit breakers observed and deemed to be GFCI’s during the inspection. And report the presence of solid conductor aluminum branch circuit wiring if readily visible. And report on any GFCI-tested receptacles in which power is not present, polarity is incorrect, the receptacle is not grounded, is not secured to the wall, the cover is not in place, the ground fault circuit interrupter devices are not properly installed or do not operate properly, or evidence of arcing or excessive heat is present. The service entrance conductors and the condition of their sheathing. The ground fault circuit interrupters observed and deemed to be GFCI’s during the inspection with a GFCI tester. And describe the amperage rating of the service. And report the absence of smoke detectors. Service entrance cables and report as in need of repair deficiencies in the integrity of the insulation, drip loop, or separation of conductors at weatherheads and clearances.

The inspector is not required to: Insert any tool, probe or device into the main panel, sub-panels, downstream panel, or electrical fixtures. Operate electrical systems that are shut down. Remove panel covers or dead front covers if not readily accessible. Operate over current protection devices. Operate non-accessible smoke detectors. Measure or determine the amperage or voltage of the main service if not visibly labeled. Inspect the alarm system and components. Inspect the ancillary wiring or remote control devices. Activate any electrical systems or branch circuits which are not energized. Operate overload devices. Inspect low voltage systems, electrical de-icing tapes, swimming pool wiring or any time-controlled devices. Verify the continuity of the connected service ground. Inspect private or emergency electrical supply sources, including but not limited to generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. Inspect spark or lightning arrestors. Conduct voltage drop calculations. Determine the accuracy of breaker labeling. Inspect exterior lighting.

Styles & Materials
Below ground
Panel Capacity:
150 AMP
Panel Type:
Circuit breakers
Electric Panel Manufacturer:
GENERAL ELECTRIC
Branch wire 15 and 20 AMP:
Copper
Wiring Methods:
Romex

 

IN

NI

NP

RR

6.0

Service Entrance Conductors

6.1

Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution Panels

6.2

Branch Circuit Conductors, Overcurrent Devices and Compatability of their Amperage and Voltage

6.3

Connected Devices and Fixtures (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling’s exterior walls)

6.4

Polarity and Grounding of Receptacles within 6 feet of interior plumbing fixtures, all receptacles in garage, carport and exterior walls of inspected structure

6.5

Operation of GFCI (Ground Fault Circuit Interrupters)

6.6

Operation of AFCI (ARC Fault Circuit Interrupters)

6.7

Location of Main and Distribution Panels

6.8

Smoke Detectors

IN

NI

NP

RR

IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

Comments:

6.1 (1)  The sub panel had doubled wiring at circuit(s), and missing breaker(s). I recommend a licensed electrical contractor inspect further and correct as needed.

 

6.1 Item 1 (Picture)                                  6.1 Item 2 (Picture)
6.1 (2)  The sub panel had knock-outs missing on panel in the garage. I recommend a licensed electrical contractor inspect further and correct as needed.
6.1 Item 3 (Picture)
6.4 (1)  The exterior outlet at the left side of home and rear of home did not work or there is no power to outlet. This is for your information. I recommend repair as needed.
6.4 Item 1 (Picture)                               6.4 Item 2 (Picture)                               6.4 Item 3 (Picture)
6.4 (2)  Several outlets at the exterior were not GFCI protected. All outlets in wet locations (kitchens, bathrooms, laundry rooms, exterior) should be GFCI or GFCI protected. I recommend repair as needed.
6.4 Item 4 (Picture)                              6.4 Item 5 (Picture)                              6.4 Item 6 (Video)
6.4 (3)  The receptacle outlet at the Garage is missing knockout(s). This is a safety issue that needs to be corrected. I recommend repair as needed.

6.4 Item 7 (Picture)
6.6 (1)  The main panel box is located at the West side of the home.
6.6 (2)  The sub panel box is located at the den.
6.8
The smoke detectors should be tested upon moving in to home. The batteries should be replaced annually and the smoke detector should be replaced every 10 years.
The electrical system of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Outlets were not removed and the inspection was only visual. Any outlet not accessible (behind the refrigerator for example) was not inspected or accessible. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

7. Insulation and Ventilation

The home inspector shall observe: Insulation and vapor retarders in unfinished spaces; Ventilation of attics and foundation areas; Kitchen, bathroom, and laundry venting systems; and the operation of any readily accessible attic ventilation fan, and, when temperature permits, the operation of any readily accessible thermostatic control. The home inspector shall describe: Insulation in unfinished spaces; and Absence of insulation in unfinished space at conditioned surfaces. The home inspector shall: Move insulation where readily visible evidence indicates the need to do so; and Move insulation where chimneys penetrate roofs, where plumbing drain/waste pipes penetrate floors, adjacent to earth filled stoops or porches, and at exterior doors. The home inspector is not required to report on: Concealed insulation and vapor retarders; or Venting equipment that is integral with household appliances.
Styles & Materials
Off Ridge Vents
Exhaust Fans:
Fan only
Dryer Power Source:
220 Electric
Dryer Vent:
Flexible Metal

 

IN

NI

NP

RR

7.0

Insulation in Attic

7.1

Ventilation of Attic and Foundation Areas

7.2

Venting Systems (Kitchens, Baths and Laundry)

7.3

Ventilation Fans and Thermostatic Controls in Attic

IN

NI

NP

RR

IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

Comments:

7.0  Insulation is missing in one area above the kitchen. Heat or cool loss can occur more on this home than one that is properly insulated. A qualified person should repair or replace as needed.

7.0 Item 1 (Picture)                                                 7.0 Item 2 (Picture)                                                   7.0 Item 3 (Picture)                                                  7.0 Item 4 (Picture)
The insulation and ventilation of the home
was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Venting of exhaust fans or clothes dryer cannot be fully inspected and bends or obstructions can occur without being accessible or visible (behind wall and ceiling coverings). Only insulation that is visible was inspected. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

 

8. Interiors

The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments.

The inspector shall: Open and close a representative number of doors and windows. Inspect the walls, ceilings, steps, stairways, and railings. Inspect garage doors and garage door openers by operating first by remote (if available) and then by the installed automatic door control. And report as in need of repair any installed electronic sensors that are not operable or not installed at proper heights above the garage door. And report as in need of repair any door locks or side ropes that have not been removed or disabled when garage door opener is in use. And report as in need of repair any windows that are obviously fogged or display other evidence of broken seals.

The inspector is not required to: Inspect paint, wallpaper, window treatments or finish treatments. Inspect central vacuum systems. Inspect safety glazing. Inspect security systems or components. Evaluate the fastening of countertops, cabinets, sink tops and fixtures, or firewall compromises. Move furniture, stored items, or any coverings like carpets or rugs in order to inspect the concealed floor structure. Move drop ceiling tiles. Inspect or move any household appliances. Inspect or operate equipment housed in the garage except as otherwise noted. Verify or certify safe operation of any auto reverse or related safety function of a garage door. Operate or evaluate security bar release and opening mechanisms, whether interior or exterior, including compliance with local, state, or federal standards. Operate any system, appliance or component that requires the use of special keys, codes, combinations, or devices. Operate or evaluate self-cleaning oven cycles, tilt guards/latches or signal lights. Inspect microwave ovens or test leakage from microwave ovens. Operate or examine any sauna, steam-jenny, kiln, toaster, ice-maker, coffee-maker, can-opener, bread-warmer, blender, instant hot water dispenser, or other small, ancillary devices. Inspect elevators. Inspect remote controls. Inspect appliances. Inspect items not permanently installed. Examine or operate any above-ground, movable, freestanding, or otherwise non-permanently installed pool/spa, recreational equipment or self-contained equipment. Come into contact with any pool or spa water in order to determine the system structure or components. Determine the adequacy of spa jet water force or bubble effect. Determine the structural integrity or leakage of a pool or spa.

Styles & Materials
Ceiling Materials:
Drywall
Wall Material:
Drywall
Floor Covering(s):
Tile
Interior Doors:
Hollow core
Wood
Window Types:
Single pane
Window Manufacturer:
UNKNOWN
Cabinetry:
Wood
Countertop:
Granite

 

IN

NI

NP

RR

8.0

Ceilings

8.1

Walls

8.2

Floors

8.3

Steps, Stairways, Balconies and Railings

8.4

Counters and Cabinets (representative number)

8.5

Doors (representative number)

8.6

Windows (representative number)

IN

NI

NP

RR

IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

The interior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructed from view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

9. Garage

Styles & Materials
Garage Door Type:
Two automatic
Garage Door Material:
Metal

 

IN

NI

NP

RR

9.0

Garage Ceilings

9.1

Garage Walls (including Firewall Separation)

9.2

Garage Floor

9.3

Garage Door (s)

9.4

Occupant Door (from garage to inside of home)

9.5

Garage Door Operators (Report whether or not doors will reverse when met with resistance)

IN

NI

NP

RR

IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

Comments:

9.5 (1)
The garage door will reverse when met with resistance.
9.5 Item 1 (Video)
9.5 (2)
The sensors are in place for garage door and will reverse the door.
9.5 Item 2 (Video)

10. Built-In Kitchen Appliances

Styles & Materials
Dishwasher Brand:
MAYTAG
Serial # : F71808485
Dishwasher Model Number:
MODEL NUMBER
Model # : MDB8979SFZ2
Disposer Brand:
BADGER
Serial # : 16071349732
Disposer Model Number:
MODEL NUMBER
Model # : 143052-1
Range/Oven:
MAYTAG
Serial # : R61211350
Range Model Number:
MODEL NUMBER
Model # : MER8850DS1
Built in Microwave:
MAYTAG
Serial # : TR 7 03 10123
Mocrowave Model Number:
MODEL NUMBER
Model # : MMV6190FZ-1

 

IN

NI

NP

RR

10.0

Dishwasher

10.1

Ranges/Ovens/Cooktops

10.2

Food Waste Disposer

10.3

Microwave Cooking Equipment

10.4

Refrigerator

IN

NI

NP

RR

IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace

Comments:

10.1  The anti tip bracket is missing. This bracket is used to prevent the range from tipping forward and potentially spilling hot contents. I recommend repair as needed.
 
10.1 Item 1 (Picture)                                                10.1 Item 2 (Picture)
The built-in appliances of the home were inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

 

Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Jay Peters

2020 Inspection Solutions5717 Jones Rd.
Saint Cloud Florida 34771
321-877-6247

Report Attachments

ATTENTION: This inspection report is incomplete without reading the information included herein at these links/attachments. Note If you received a printed version of this page and did not receive a copy of the report through the internet please contact your inspector for a printed copy of the attachments